What are the instructions for use of the vibrating plate controller?

Author: Hechang vibrating plate      ComeFrom: www.hechangzd.com      Date:2016/6/30 13:39:58Hits:4066

1. Connection description:

      The input is a single-phase AC three-core plug, and the grounding terminal must be well grounded. The output interface is a Φ16 3-pin aviation socket. The 1 and 3 pins of the socket are connected to the input lead of the electromagnet, and the 2 pins are connected to the vibration plate casing (ground).    

      Vibration plate general controllers are commonly used in vibration plate The vibration frequency and stability of the vibration plate are not very high. In addition, there are various types of frequency modulation and digital voltage regulating controllers, etc., which can adapt to various different environments and customer requirements for vibration.


Two. Precautions for the use of vibrating disk controller:

1. The controller cannot be installed and used in an open-air environment. When connecting, be sure to cut off the power supply
2. The controller should be used in a very good ventilation and heat dissipation environment, with an ambient temperature of -20°C to 40°C.
3. The controller must not be connected to 380V AC, otherwise it will cause irreversible damage to the machine!
4. When adjusting the output waveform control selection (full wave/half wave) switch inside the machine, be sure to cut off the power supply.
5. The FG terminal of the controller input terminal must be grounded correctly. The FG terminal of the output end must be connected to the vibration plate casing.
6. The controller should be used in an environment without water droplets, steam, corrosive, flammable gases, liquids, and floating dust and metal particles.
7. The controller is only used to drive electromagnetic vibrating feeding equipment, not for other purposes.  


Three, adjustment instructions:

      After the wiring is installed, adjust the external full-wave/half-wave control selection switch as needed to make the drive output work in full-wave or half-wave mode, and adjust the amplitude control knob to a smaller position ( Near the scale 0). Turn on the power switch and the power indicator will light up. Adjust the amplitude control knob (clockwise to expand the output, on the contrary, counterclockwise to decrease the output), so that the vibration plate< /strong> Work at the required vibration speed.