Analysis of several common failures of hardware vibration plate

Author: Hechang vibrating plate      ComeFrom: www.hechangzd.com      Date:2016/6/30 13:39:38Hits:3949

Common faults of hardware vibration plate Check whether the fuse of the electric controller is blown, whether the electrical component is loose, and whether the plug and socket are in bad contact. If the conveying speed is not up to the requirements, please pay attention to the following points:

1. The unequal interval between the electromagnetic and the armature is too large, and the coil is easy to be discarded;


2. The electromagnet adapted to full-wave vibration will have a high temperature if it is used in a half-wave power supply;

3. Check whether the screws that fasten the elastic elements are loose;

4. Is the spring sheet broken;

5. Is the electromagnetic gap too large, the normal gap is symmetrical and small vibration plate The distance between the iron and the armature is in the range of 0.5mm to 1.2mm; the non-parallelism between the iron core and the armature working surface is not higher than 0.02mm;

Previous: How does the vibrating plate work?
Next: How does the vibrating plate realize the automated process?